[Home ] [Archive]   [ فارسی ]  
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
Main Menu
Home::
Journal Information::
Articles archive::
For Authors::
For Reviewers::
Registration::
Contact us::
Site Facilities::
Ethics::
peer-review::
Indexing::
Article types::
::
Search in website

Advanced Search
..
Receive site information
Enter your Email in the following box to receive the site news and information.
..
Journal DOI

AWT IMAGE

..
Copyright Policy
This work is licensed under a Creative Commons Attribution-NonCommercial 3.0 
This Journal is licensed under a Creative Commons Attribution-NonCommercial 4.0
..
:: Volume 23, Issue 1 (3-2021) ::
J Babol Univ Med Sci. 2021; Volume 23 Back to browse issues page
A Case Report of Endotracheal Tube Cuff Herniation During Lumbar Discectomy
H Feizi , S Zarei , M Moradi , B Gholamveisi *
4. Department of Operation Room, Faculty of Nursing and Midwifery, Kurdistan University of Medical Sciences, Sanandaj, I.R.Iran , Behzad.gholamveisi@gmail.com
Abstract:   (2917 Views)
BACKGROUND AND OBJECTIVE: Damage to the endotracheal tube cuff during general anesthesia can cause ventilatory failure for the patient. The aim of this study is to report structural defect and herniation of the endotracheal tube cuff in a patient undergoing lumbar discectomy in the prone position.
CASE REPORT: The patient was a 77-year-old woman who was a candidate for Lumbar discectomy who referred to Kowsar Hospital in Sanandaj for surgery. The patient underwent general anesthesia with a spiral endotracheal tube in the prone position. After 30 minutes of surgery, there were symptoms of increased airway pressure, decreased saturation, and increased carbon dioxide. Postoperative examinations revealed that the patient's endotracheal tube cuff had a hernia which blocked the airway; the problem was resolved and surgery continued. Diagnosis and treatment of this case have important and significant points that are mentioned below.
CONCLUSION: Structural defects in the endotracheal tube and its cuff may cause insufficient ventilation of the patient and reduce the delivery of anesthetic gases to the patient. The definitive solution to endotracheal tube cuff defect is replacement, but conservative measures may be used as a temporary solution in some clinical situations. The anesthesia team should be prepared with adequate equipment, programs, and personnel to follow “​Guidelines for Management of the Difficult Airway” developed by the American Society of Anesthesiologists (ASA) in the case of loss of air exchange in the patient.
Keywords: Endotracheal Intubation, Endotracheal Tube Cuff, Airway, Complications.
Full-Text [PDF 280 kb]   (1032 Downloads)    
Type of Study: case report | Subject: Anesthesia
Received: 2020/09/27 | Accepted: 2020/12/22 | Published: 2021/07/3
Send email to the article author



XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Feizi H, Zarei S, Moradi M, Gholamveisi B. A Case Report of Endotracheal Tube Cuff Herniation During Lumbar Discectomy. J Babol Univ Med Sci 2021; 23 (1) :164-168
URL: http://jbums.org/article-1-9655-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 23, Issue 1 (3-2021) Back to browse issues page
مجله علمی دانشگاه علوم پزشکی بابل Journal of Babol University of Medical Sciences

The Journal of Babol University of Medical Sciences is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Persian site map - English site map - Created in 0.05 seconds with 43 queries by YEKTAWEB 4660