[Home ] [Archive]   [ فارسی ]  
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
Main Menu
Home::
Journal Information::
Articles archive::
For Authors::
For Reviewers::
Registration::
Contact us::
Site Facilities::
Ethics::
peer-review::
Indexing::
Article types::
::
Search in website

Advanced Search
..
Receive site information
Enter your Email in the following box to receive the site news and information.
..
Journal DOI

AWT IMAGE

..
Copyright Policy
This work is licensed under a Creative Commons Attribution-NonCommercial 3.0 
This Journal is licensed under a Creative Commons Attribution-NonCommercial 4.0
..
:: Volume 4, Issue 1 (1-2002) ::
J Babol Univ Med Sci. 2002; Volume 4 Back to browse issues page
Sensitivity and specificity of NST in cases with decrease of fetal movement and amniotic fluid volume
T Naderi * , Y Nikian , F Amin Zadeh
Abstract:   (8637 Views)
Background and Objective: Non Stress Test (NST) is the most common test before delivery that is done in some cases with probability of fetal distress. The objective of this study was to determine the sensitivity and specificity of NST in cases with complaint of decreased fetal movement or decrease of amniotic fluid volume according to sonography report. Methods: This cross-sectional study was done on 120 women referred to Bahonar hospital in Kerman. It was performed on all pregnant women with gestational age of 38-42 who complained of decrease of fetal movement (84.2%) and a decrease of amniotic fluid volume (61%) was reported in their sonography. Findings: The result of NST in 64.1% of patients was non-reactive and in 35.9% was reactive. 41.7% of cases were with fetal distress during labor or delivery, of which 94.1% had non-reactive NST. The sensitivity and specificity of NST in cases with decrease of amniotic fluid were 89% and 74.5%, respectively and in cases with complaint of decreased fetal movement were 63.4% and 32%, 7 respectively. Conclusion: Exact heart rate monitor in cases with complaint of decreased fetal movement or amniotic fluid volume and also with non-reactive NST in necessary.
Keywords: NST, Fetal movement, Oligohydramnios
Full-Text [PDF 244 kb]   (2994 Downloads)    
Type of Study: Research | Subject: Biochemical
Accepted: 2014/05/27 | Published: 2014/05/27


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Naderi T, Nikian Y, Amin Zadeh F. Sensitivity and specificity of NST in cases with decrease of fetal movement and amniotic fluid volume. J Babol Univ Med Sci 2002; 4 (1) :7-10
URL: http://jbums.org/article-1-2836-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 4, Issue 1 (1-2002) Back to browse issues page
مجله علمی دانشگاه علوم پزشکی بابل Journal of Babol University of Medical Sciences

The Journal of Babol University of Medical Sciences is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Persian site map - English site map - Created in 0.06 seconds with 43 queries by YEKTAWEB 4660