[Home ] [Archive]   [ فارسی ]  
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
Main Menu
Home::
Journal Information::
Articles archive::
For Authors::
For Reviewers::
Registration::
Contact us::
Site Facilities::
Ethics::
peer-review::
Indexing::
Article types::
::
Search in website

Advanced Search
..
Receive site information
Enter your Email in the following box to receive the site news and information.
..
Journal DOI

AWT IMAGE

..
Copyright Policy
This work is licensed under a Creative Commons Attribution-NonCommercial 3.0 
This Journal is licensed under a Creative Commons Attribution-NonCommercial 4.0
..
:: Volume 6, Issue 3 (7-2004) ::
J Babol Univ Med Sci. 2004; Volume 6 Back to browse issues page
Comparison of different computer speeds in calculating of Co 60 depth doses by MCNP4A and MCNP4B Monte Carlo codes
A Mesbahi * , R Mahdavi , M Allahverdi
Abstract:   (7550 Views)
Background and Objective: MCNP is a general-purpose Monte Carlo code that is used for simulating of neutrons, photons and electrons transport in different media. Recently this code has been used for radiotherapy dosimetry and treatment planning. In recent investigations, the reasonable run-time was not acquired for clinical use of Monte Carlo method. In this research, the speeds of the computers available in Iran were compared in running a percent depth dose calculation (PPD) for CO60 teletherapy machine. Methods: Geometry of a typical CO60 teletherapy machine and a water phantom were simulated. Both version of MCNP code were installed on Pentium 233, 866, 1500 MHz, 700 MHz Duran and Athelon 1333MHz personal computers. Percent depth dose of CO60 gamma rays in water phantom for 10×10 cm was calculated by each computer. Findings: The time required to computer the PDD by F6 tally was 60 times greater than the F8 tally. In all the cases, the 4A version was approximately 5% faster than 4B version. This suggests that in radiotherapy application like our test problem there is not considerable computing time difference between 4A and 4B version. Conclusion: The results recommend the use of F6 tally in radiotherapy application by CO60 gamma rays where the point of interest are not situated in electronic disequilibrium regions and when the time of calculation is important.
Keywords: Monte Carlo simulation, MCNP, Radiotherapy dosimetry, Depth dose
Full-Text [PDF 455 kb]   (2702 Downloads)    
Type of Study: Research | Subject: Biochemical
Accepted: 2014/05/31 | Published: 2014/05/31


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Mesbahi A, Mahdavi R, Allahverdi M. Comparison of different computer speeds in calculating of Co 60 depth doses by MCNP4A and MCNP4B Monte Carlo codes. J Babol Univ Med Sci 2004; 6 (3) :7-11
URL: http://jbums.org/article-1-2675-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 6, Issue 3 (7-2004) Back to browse issues page
مجله علمی دانشگاه علوم پزشکی بابل Journal of Babol University of Medical Sciences

The Journal of Babol University of Medical Sciences is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Persian site map - English site map - Created in 0.05 seconds with 43 queries by YEKTAWEB 4660