[Home ] [Archive]   [ فارسی ]  
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
Main Menu
Home::
Journal Information::
Articles archive::
For Authors::
For Reviewers::
Registration::
Contact us::
Site Facilities::
Ethics::
peer-review::
Indexing::
::
Search in website

Advanced Search
..
Receive site information
Enter your Email in the following box to receive the site news and information.
..
Journal DOI

AWT IMAGE

..
Copyright Policy
This work is licensed under a Creative Commons Attribution-NonCommercial 3.0 
This Journal is licensed under a Creative Commons Attribution-NonCommercial 4.0
..
:: Volume 7, Issue 2 (4-2005) ::
J Babol Univ Med Sci. 2005; Volume 7 Back to browse issues page
Measurement of total plasma Homocysteine with reverse phase high performance liquid chromatography (RP-HPLC) method without internal standard
F Darabi * , B Jalali , M Rafiei , M Mahdavi , A Babaei
Abstract:   (7787 Views)
Background and Objective: Homocysteine is an amino acid with a free thiol (Sulphydryl) group and is an intermediate formed during the metabolism of methionine to cysteine. Measurement of total plasma Homocysteine may be of value in several clinical conditions including homocysteinuria, atherosclerosis, thrombophilia and folate/vitamin B12 deficiency. The purpose of this study was to measure total plasma Homocysteine using RP-HPLC with fluorescence detection method. Methods: Total plasma Homocysteine was measured with reverse-phase HPLC with fluorescence detection after reduction of Homocysteine with tris (2-carboxyetile) phosphine (TCEP) and derivatization of plasma thiols with ammonium 7-fluorobenzo-2-oxa 1,3-diazole-4-sulfonate (SBD-F). Findings: The limit of detection for Homocysteine was 0.2 µmol/l. The within day coefficient of variation (CV) was 2.67% to 4.56% and the between day coefficient of variation was 5.43% to 8.17%. The mean recovery of Homocysteine was 93% to 103.4%. Conclusion: The results show that the HPLC method with fluorescence detection for measurement of total plasma Homocysteine, is sensitive (The limit of detection 0.2 µmol/l), accurate (CV between 2.67% and 8.17%) and it has acceptable recovery (93% to 103.4%). Therefore, it is confident method especially for investigate application.
Keywords: Homocysteine, Atherosclerosis, High performance liquid chromatography, Plasma
Full-Text [PDF 979 kb]   (1722 Downloads)    
Type of Study: Research | Subject: Biochemical
Accepted: 2014/05/31 | Published: 2014/05/31


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Darabi F, Jalali B, Rafiei M, Mahdavi M, Babaei A. Measurement of total plasma Homocysteine with reverse phase high performance liquid chromatography (RP-HPLC) method without internal standard. J Babol Univ Med Sci 2005; 7 (2) :18-23
URL: http://jbums.org/article-1-2632-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 7, Issue 2 (4-2005) Back to browse issues page
مجله علمی دانشگاه علوم پزشکی بابل Journal of Babol University of Medical Sciences

The Journal of Babol University of Medical Sciences is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Persian site map - English site map - Created in 0.06 seconds with 43 queries by YEKTAWEB 4645