[Home ] [Archive]   [ فارسی ]  
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
Main Menu
Home::
Journal Information::
Articles archive::
For Authors::
For Reviewers::
Registration::
Contact us::
Site Facilities::
Ethics::
peer-review::
Indexing::
Article types::
::
Search in website

Advanced Search
..
Receive site information
Enter your Email in the following box to receive the site news and information.
..
Journal DOI

AWT IMAGE

..
Copyright Policy
This work is licensed under a Creative Commons Attribution-NonCommercial 3.0 
This Journal is licensed under a Creative Commons Attribution-NonCommercial 4.0
..
:: Volume 26 - ::
J Babol Univ Med Sci. 2024; Volume 26 Back to browse issues page
Frictional Resistance of Two Types of Esthetic Self-Ligating Brackets
HA Kamil * , ShSh Taha
1.Department of Orthodontics, College of Dentistry, University of Baghdad, Baghdad, Iraq. , heba.Ali1203a@codental.uobaghdad.edu.iq
Abstract:   (264 Views)
Background and Objective: Friction between the archwire and bracket is the main problem during tooth movement. Self-ligating bracket systems have become common in recent years. The aim of this study was to investigate and compare the effect of active and passive esthetic self-ligating brackets on static frictional force with different orthodontic archwires under wet conditions.
Methods: This in vitro study included 180 ceramic self-ligating brackets, 90 passive brackets (Damon Clear), and 90 active brackets (Empower Clear), which were tested for frictional resistance using three different types of 0.018-inch archwires, namely copper NiTi archwires and two esthetic archwires (Epoxy- and rhodium-coated NiTi archwires). According to the types of brackets and archwires, six groups of ten were defined. An experimental model with three non-leveled brackets in wet condition using artificial saliva was adopted. The friction test was conducted by Instron Tinius Olsen testing device. The test was performed at a room temperature ranging from 24-25°C.
Findings: Empower clear with Cu NiTi archwire showed the highest mean value of static frictional force with the mean value of (327.85±53.43) and Damon clear with epoxy coated NiTi archwire showed the lowest mean value (58.06±10.87). There were significant differences in the static frictional forces generated in both bracket systems when coupled with the Epoxy wires (p=0.000) and when coupled with the CuNiTi and Rhodium archwires (p=0.001).
Conclusion: The result of this study showed that the Damon Clear brackets produce lower frictional forces than Empower Clear brackets and Epoxy-coated NiTi archwires can produce lower static frictional force compared to Rhodium-coated NiTi and CuNiTi archwires.

 
Keywords: Friction, Coated Archwire, Ceramic Bracket, Self-Litigating Bracket.
Full-Text [PDF 359 kb]   (35 Downloads)    
Type of Study: Research | Subject: Dentistry (Pathology)
Received: 2023/07/2 | Accepted: 2023/10/7 | Published: 2024/09/10
Send email to the article author


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Kamil H, Taha S. Frictional Resistance of Two Types of Esthetic Self-Ligating Brackets. J Babol Univ Med Sci 2024; 26
URL: http://jbums.org/article-1-11479-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 26 - Back to browse issues page
مجله علمی دانشگاه علوم پزشکی بابل Journal of Babol University of Medical Sciences

The Journal of Babol University of Medical Sciences is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Persian site map - English site map - Created in 0.05 seconds with 43 queries by YEKTAWEB 4660