[Home ] [Archive]   [ فارسی ]  
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
Main Menu
Home::
Journal Information::
Articles archive::
For Authors::
For Reviewers::
Registration::
Contact us::
Site Facilities::
Ethics::
peer-review::
Indexing::
::
Search in website

Advanced Search
..
Receive site information
Enter your Email in the following box to receive the site news and information.
..
Journal DOI

AWT IMAGE

..
Copyright Policy
This work is licensed under a Creative Commons Attribution-NonCommercial 3.0 
This Journal is licensed under a Creative Commons Attribution-NonCommercial 4.0
..
:: Volume 22, Issue 1 (3-2020) ::
J Babol Univ Med Sci. 2020; Volume 22 Back to browse issues page
Enhancing the Accuracy of Vascular Embolism Volumetry Using Medical Imaging Software
SF Ayatifard , M Pezeshkirad , M Amini , N Morovatdar , J Pirayesh Islamian *
5. Immunology Research Center, Tabriz University of Medical Sciences, Tabriz, I.R.Iran , pirayeshj@tbzmed.ac.ir
Abstract:   (2757 Views)
BACKGROUND AND OBJECTIVE: Detecting and accurate determining of vascular embolism dimensions are considered as a challenging issue in CT imaging. Present study aimed to enhance the accuracy of vascular embolism volumetry in managing a proper diagnosis and treatment of the disease.
METHODS: In this non experimental quantitative study, firstly we simulated coronary and aorta arteries with normal dimensions in a 4D extended NURBS based cardiac-torso phantom in a matrix sizes of 512×512 with slice thickness of 0.116 mm. Then, twenty five venous thromboembolisms with the diameters ranged 0.1-5 and 5-20 mm were created in the coronary arteries and aorta of the Phantom, respectively. The Medical Imaging Interaction Toolkit was used for localization and volume measurement of the produced venous thromboembolisms on the CT images. Finally, Accuracy of the measured data was compared with the simulated measures in the phantom.
FINDINGS: The difference on measures with the software was obtained 0.03±0.021 for embolies less than 4.64 mm (0.1 ml), (r=0.67, p=0.02), and 0.02±0.008 mm for embolies greater than 4.64 mm (r=0.99, p<0.001).
CONCLUSION: According to the acceptable volumetry accuracy of Medical Imaging Interaction Toolkit especially for volumes greater than 0.1 ml, may be used for an accurate thromboembolism and pulmonary embolism measurements.
Keywords: Embolism, Volumetry, Medical Diagnosis, Coronary Vessels, Aorta.
Full-Text [PDF 509 kb]   (671 Downloads)    
Type of Study: Research | Subject: Medical Physics
Received: 2019/07/21 | Accepted: 2019/10/22 | Published: 2020/10/19
Send email to the article author



XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Ayatifard S, Pezeshkirad M, Amini M, Morovatdar N, Pirayesh Islamian J. Enhancing the Accuracy of Vascular Embolism Volumetry Using Medical Imaging Software. J Babol Univ Med Sci 2020; 22 (1) :195-202
URL: http://jbums.org/article-1-8875-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 22, Issue 1 (3-2020) Back to browse issues page
مجله علمی دانشگاه علوم پزشکی بابل Journal of Babol University of Medical Sciences

The Journal of Babol University of Medical Sciences is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Persian site map - English site map - Created in 0.07 seconds with 43 queries by YEKTAWEB 4645