<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Babol University of Medical Sciences</title>
<title_fa>مجله علمی دانشگاه علوم پزشکی بابل</title_fa>
<short_title>J Babol Univ Med Sci</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jbums.org</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1561-4107</journal_id_issn>
<journal_id_issn_online>2251-7170</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.22088/jbums</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1392</year>
	<month>6</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2013</year>
	<month>9</month>
	<day>1</day>
</pubdate>
<volume>15</volume>
<number>5</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>رابطه بین مقیاس کلینیکی و شاخصهای الکترومیوگرافی در ارزیابی اسپاستیسیته بعد از سکته مغزی</title_fa>
	<title>Relationship between Clinical Scale and Electromyographic Parameters in Assessing Spasticity after Stroke- Brief Report</title>
	<subject_fa>بیوشیمی</subject_fa>
	<subject>Biochemical</subject>
	<content_type_fa>تحلیلی</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>سابقه و هدف: اسپاستیسیته یکی از اختلالات شایع حرکتی می باشد که در 30-20 درصد بیماران مبتلا به سکته مغزی رخ می دهد. مقیاس اصلاح شده اصلاح شده اشورث (MMAS) یک تست کلینیکی جدید برای اندازه گیری اسپاستیسیته عضلانی است که به طور فزاینده ای در کلینیک و تحقیقات استفاده می شود. این مطالعه به منظور بررسی رابطه بین مقیاس MMAS و پارامترهای الکترومیوگرافی (EMG) در ارزیابی اسپاستیسیته عضله فلکسور مچ انجام شد.&lt;br&gt;مواد و روشها: در این تحقیق که از نوع بررسی اعتبار معیار همزمان می باشد، 11 بیمار زن با همی پلژی ناشی از اولین سکته مغزی شرکت کردند. اسپاستیسیته عضلات فلکسور مچ دست مبتلای بیماران، با استفاده از مقیاسMMAS همزمان با ثبت EMG ارزیابی گردید. همبستگی درجات مقیاس MMAS با پارامترهای الکترومیوگرافی مقایسه شد.&lt;br&gt;یافته ها: میانگین سنی بیماران 11±82/51 سال (دامنه 69-32) و میانگین مدت ابتلا 6/19±82/17 ماه (دامنه 48–1) بود، همبستگی معنی داری بین مقیاس MMAS و همه پارامترهای الکترومیوگرافی شامل میانگین دامنه (02/0, p=64/0r=)، حداکثر دامنه (05/0, p=53/0r=)، مدت زمان فعالیت الکتریکی (01/0p=، 72/0r=)، زمان تاخیری (01/0p=، 69/0=r=) و زمان صعود دامنه (04/0p=، 56/0=r) وجود داشت.&lt;br&gt;نتیجه گیری: براساس نتایج این مطالعه مقیاس اصلاح شده اشورث معیار معتبری برای ارزیابی اسپاستیسیته می باشد.&lt;br&gt;</abstract_fa>
	<abstract>BACKGROUND AND OBJECTIVE: The Modified Modified Ashworth Scale (MMAS) is a new clinical test for measuring muscle spasticity, which is increasingly used in the clinic and research. Only one study has been performed on the validity of the MMAS. The aim of the present study was to investigate the relationship between the MMAS and electromyographic (EMG) parameters in assessing wrist flexor muscle spasticity.&lt;br&gt;METHODS: In this concurrent criterion-related validity study, eleven women with first ever stroke resulted in hemiplegia with a mean age 51.82 years (range: 32-69) and mean time since stroke 17.82 months (range: 1-48) participated. Spasticity of wrist flexors using MMAS simultaneously with EMG recordings was assessed. Spearmans rho test was used to calculate the correlations between the MMAS grades and EMG parameters. &lt;br&gt;FINDINGS: There were significant correlations between the MMAS and all EMG parameters including mean amplitude (r=0.64, p=0.02), peak amplitude (r=0.53, p=0.05), duration of activity (r=0.72, p=0.01), latency (r=-0.69, &lt;br&gt;p=0.01), and rise time (r=0.56, p=0.04).&lt;br&gt;CONCLUSION: The significant correlations between the MMAS and the EMG parameters indicate that the MMAS is a valid measure for assessing muscle spasticity.&lt;br&gt;</abstract>
	<keyword_fa>سکته مغزی, اسپاستیسیته, مقیاس اصلاح شده اصلاح شده اشورث, اعتبار, الکترومیوگرافی سطحی.</keyword_fa>
	<keyword>Stroke, Spasticity, Modified modified ashworth scale, Validity, Surface electromyography</keyword>
	<start_page>84</start_page>
	<end_page>88</end_page>
	<web_url>http://jbums.org/browse.php?a_code=A-10-1370-921&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>N</first_name>
	<middle_name></middle_name>
	<last_name> Nakhostin</last_name>
	<suffix></suffix>
	<first_name_fa>نورالدین </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>نخستین انصاری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>10031947532846004971</code>
	<orcid>10031947532846004971</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>S</first_name>
	<middle_name></middle_name>
	<last_name>Naghdi</last_name>
	<suffix></suffix>
	<first_name_fa> صوفیا </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>نقدی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>10031947532846004972</code>
	<orcid>10031947532846004972</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>J</first_name>
	<middle_name></middle_name>
	<last_name> Sarrafzadeh</last_name>
	<suffix></suffix>
	<first_name_fa>جواد</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa> صراف زاده </last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>10031947532846004973</code>
	<orcid>10031947532846004973</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>A</first_name>
	<middle_name></middle_name>
	<last_name> Mousakhani </last_name>
	<suffix></suffix>
	<first_name_fa>عاطفه</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa> موسی خانی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>10031947532846004974</code>
	<orcid>10031947532846004974</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
