[Home ] [Archive]   [ فارسی ]  
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
Main Menu
Home::
Journal Information::
Articles archive::
For Authors::
For Reviewers::
Registration::
Contact us::
Site Facilities::
Ethics::
peer-review::
Indexing::
::
Search in website

Advanced Search
..
Receive site information
Enter your Email in the following box to receive the site news and information.
..
Journal DOI

AWT IMAGE

..
Copyright Policy
This work is licensed under a Creative Commons Attribution-NonCommercial 3.0 
This Journal is licensed under a Creative Commons Attribution-NonCommercial 4.0
..
:: Volume 16, Issue 3 (3-2014) ::
J Babol Univ Med Sci. 2014; Volume 16 Back to browse issues page
Effect of Vitamin B1 on Pain after Insertion of Intrauterine Device
A Jafari * , M Sayyahi , R Torkashvand , H Piryaei
Abstract:   (6477 Views)
BACKGROUND AND OBJECTIVE: Intrauterine device (IUD) has a wide use in qualified women to prevent pregnancy around the world. Pain is one of the main reasons why women avoid using copper intrauterine device continuously. So, strategies to reduce pain are necessary. The aim of this study was to determine the effect of vitamin B1 on the pain caused by intrauterine device insertion.
METHODS: This double-blinded, randomized controlled trial was performed on 126 women aged 18 to 35 years, referring to four public clinics in Boroujerd, Iran between 2011 and 2013. The women who experienced increased menstrual pain within the first cycle after IUD insertion were randomly divided into two groups: intervention group received vitamin B1supplement (100 mg) and control group received placebo one per day for three months during the second, third and fourth cycles after IUD insertion. Samples were evaluated within 5 months with one month interval before drug intervention (after IUD insertion), 3 months after drug intervention and then 1 month later after finishing intervention (without using drug and placebo). In this study, pain intensity was measured by Visual Analog Scale. (IRCT: 2012073010451N1)
FINDINGS: In contrast, pain duration mean in intervention group from 28.75±6.54 to 9.26±3.55 and in control group from 29.02±5.49 to 21.56±3.73 were reported (p<0.001). The mean of pain intensity in intervention group from 25.5% to 0% severe pain, and in control group from 24.3% to14.1% were reported. In intervention group (79.9%) and in control group (9.6%) no pain was reported (in the fifth month) (p<0.001).Need to analgesic drug in intervention group from 44.26% to 0%, and in control group from 38.7% to 42.8% were reported (p<0.001).
CONCLUSION: The results showed that vitamin B1 is effective in reducing pain induced by IUD insertion.

Please cite this article as follows:
Jafari A, Sayyahi M, Torkashvand R, Piryaei H. Effect of vitamin B1 on pain after insertion of intrauterine device. J Babol Univ Med Sci 2014 16(3): 13-20.
Keywords: Vitamin B1, Intrauterine device, Women, Pain intensity, Pain duration.
Full-Text [PDF 471 kb]   (1480 Downloads)    
Type of Study: Research | Subject: Biochemical
Accepted: 2014/06/11 | Published: 2014/06/11



XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Jafari A, Sayyahi M, Torkashvand R, Piryaei H. Effect of Vitamin B1 on Pain after Insertion of Intrauterine Device. J Babol Univ Med Sci 2014; 16 (3) :13-20
URL: http://jbums.org/article-1-4655-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 16, Issue 3 (3-2014) Back to browse issues page
مجله علمی دانشگاه علوم پزشکی بابل Journal of Babol University of Medical Sciences

The Journal of Babol University of Medical Sciences is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Persian site map - English site map - Created in 0.06 seconds with 43 queries by YEKTAWEB 4645