[Home ] [Archive]   [ فارسی ]  
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
Main Menu
Home::
Journal Information::
Articles archive::
For Authors::
For Reviewers::
Registration::
Contact us::
Site Facilities::
Ethics::
peer-review::
Indexing::
::
Search in website

Advanced Search
..
Receive site information
Enter your Email in the following box to receive the site news and information.
..
Journal DOI

AWT IMAGE

..
Copyright Policy
This work is licensed under a Creative Commons Attribution-NonCommercial 3.0 
This Journal is licensed under a Creative Commons Attribution-NonCommercial 4.0
..
:: Volume 4, Issue 4 (10-2002) ::
J Babol Univ Med Sci. 2002; Volume 4 Back to browse issues page
Contamination of anesthetic machine with common method of disinfection in operation room, Babol, 2000-01
Y Mortazavi, * , R Rajabnia
Abstract:   (6220 Views)
Background and Objective: Nowadays, medical equipment are daily used for different patients in hospitals. Contamination can be transmitted by anesthetic equipment from one patient to another. The objective of this study was to determine the rate of contamination of anesthetic machine after using cetrimide-C as a disinfectant solution. Methods: In this descriptive and analytical study, 48 samples of the two parts of anesthetic machine were taken in 6 operation rooms of Babol Shahid Beheshti hospital. Sampling from the parts before and after sodalime was taken at the stages before and after washing with cetrimide-C as a disinfectant solution (10%). Data was analyzed by Chi-square test. Findings: According to the results, from where the samples were taken before sodalime at the stage before washing 16.7% of samples and after washing 19.4% contaminated to bacteria. Also, from the parts where the samples were taken after sodalime at the stage before washing 37.5% of cases and after washing 33.3% contaminated by bacteria that there was not statistically significant difference. Conclusion: According to the results, there was a bacterial contamination in the anesthetic machines at the stage before and after washing and it indicates that common method and using cetrimide-C as a disinfectant solution with unstandard concentration are not so effective in the decrease of contamination.
Keywords: Anesthetic machine, Disinfectant, Contamination
Full-Text [PDF 246 kb]   (2984 Downloads)    
Type of Study: Research | Subject: Biochemical
Accepted: 2014/05/27 | Published: 2014/05/27


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Mortazavi, Y, Rajabnia R. Contamination of anesthetic machine with common method of disinfection in operation room, Babol, 2000-01. J Babol Univ Med Sci 2002; 4 (4) :45-49
URL: http://jbums.org/article-1-2812-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 4, Issue 4 (10-2002) Back to browse issues page
مجله علمی دانشگاه علوم پزشکی بابل Journal of Babol University of Medical Sciences

The Journal of Babol University of Medical Sciences is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Persian site map - English site map - Created in 0.05 seconds with 43 queries by YEKTAWEB 4645