Abstract:   (1239 Views)
Background and Objective: Weropress is a pourable auto-polymerising acrylic resin which has recently been used in making dentures. It is characterised by high colour stability and quick setting. However, it is not as strong as heat-polymerised acrylic resin. The objective of this in-vitro study is to find out the effect of adding micro-glass beads on flexural strength, hardness and surface roughness of “Weropress”.
Methods: In this study, 24 65×10×3 mm specimens were produced from Weropress following the manufacturer’s instructions (casting process). The specimens were divided into 4 groups (n=6): group 1 was “control” which had no additives, group 2; 3; and 4 contained micro-glass particles at ratios 5%, 10%, and 15%. After conventional finishing and polishing procedure, all specimens were immersed in distilled water at room temperature for 2 days. Then, the surface roughness (3 times, 4mm), hardness (four times at 50 g load for 30 sec dwell time), and 3-point bending test (5mm/min speed, 50 mm heads apart) were applied on each specimen and then evaluated.
Findings: Flexural strength reduced for 97 MPa when no filler was added. When 15% filler was added, it reached 75.5 MPa, which had a significant decrease (p=0.03). Other groups showed no significant difference (79.5 MPa and 81.5 MPa). Vickers hardness was fluctuating around (16 MPa) of control following the addition of fillers; however, all testing groups were not significantly different from control. Surface roughness has increased in all groups from 0.53 µm up to 0.77 µm but with no significant difference.
Conclusion: According to results, the addition of micro-glass beads on Weropress powder at 5%, 10%, and 15% has no strengthening effect on Weropress with no important effect on hardness and surface roughness.
Keywords: Flexural Strengths, Hardness, Cold-Cured Acrylic, Denture Base Resin, Glass.
Full-Text [PDF 563 kb]   (188 Downloads)    
Type of Study: Research | Subject: Dentistry (prosthetics)
Received: 2023/08/23 | Accepted: 2024/03/2 | Published: 2025/03/16


XML   Persian Abstract   Print



Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 27 - Back to browse issues page