[Home ] [Archive]   [ فارسی ]  
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
Main Menu
Home::
Journal Information::
Articles archive::
For Authors::
For Reviewers::
Registration::
Contact us::
Site Facilities::
Ethics::
peer-review::
Indexing::
::
Search in website

Advanced Search
..
Receive site information
Enter your Email in the following box to receive the site news and information.
..
Journal DOI

AWT IMAGE

..
Copyright Policy
This work is licensed under a Creative Commons Attribution-NonCommercial 3.0 
This Journal is licensed under a Creative Commons Attribution-NonCommercial 4.0
..
:: Volume 22, Issue 1 (3-2020) ::
J Babol Univ Med Sci. 2020; Volume 22 Back to browse issues page
The Effect of Low Level Laser Ga-Al-As on the Treatment of Dentinal Sensitivity after Amalgam Restorations
HS Mohammadipour , P Mosannen Mozaffari , M Amirchaghmaghi , F Asadi , A Ghazi *
2. Oral and Maxillofacial Diseases Research Center, Mashhad University of Medical Sciences, Mashhad, I.R.Iran , ghazial@mums.ac.ir
Abstract:   (3393 Views)
BACKGROUND AND OBJECTIVE: Pain and sensitivity to thermal irritation after amalgam restoration is one of the most common problems, causes frequent recurrence of these patients to dental clinics. Since low-level laser has several benefits in reducing inflammation, pain and sensitivity, the aim of this study was to evaluate the effect of low-level Ga-Al-As laser on the treatment of dentinal sensitivity after amalgam restoration.
METHODS: In this double-blind clinical trial study, 21 patients with short-term sensitivity to thermal irritation after amalgam restoration (from the time of repair to two months) were evaluated. The case group was treated with Ga-Al-As laser in 4 sessions with intervals of three days. For the control group, the similar condition was applied except that the device was off. The sensitivity was assessed based on VAS criteria prior to treatment, immediately after treatment, and 3 and 6 months after treatment.
FINDINGS: Pre and post-treatment pain in case group was 7.3±1.16, 4.5±3.03 and in control group was 6.45±1.75, 4.27±3.04 respectively. The reduction in pain immediately after treatment was significant only in the case group (p= 0.004). In the follow-up period of 3 and 6 months, the mean VAS in the case group was significantly higher than that in the control group (p= 0.026 and p= 0.020, respectively).
CONCLUSION: Based on the results this study, the Ga-Al-As low-level laser has a decreasing effect on the sensitivity of post-amalgam restorations in a short term.
Keywords: Low-Level laser, Dental Amalgam, Hypersensitivity.
Full-Text [PDF 399 kb]   (1321 Downloads)    
Type of Study: Interventional | Subject: Restorative Dentistry
Received: 2019/01/21 | Accepted: 2020/02/1 | Published: 2020/06/16
Send email to the article author



XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Mohammadipour H, Mosannen Mozaffari P, Amirchaghmaghi M, Asadi F, Ghazi A. The Effect of Low Level Laser Ga-Al-As on the Treatment of Dentinal Sensitivity after Amalgam Restorations. J Babol Univ Med Sci 2020; 22 (1) :72-77
URL: http://jbums.org/article-1-8474-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 22, Issue 1 (3-2020) Back to browse issues page
مجله علمی دانشگاه علوم پزشکی بابل Journal of Babol University of Medical Sciences

The Journal of Babol University of Medical Sciences is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Persian site map - English site map - Created in 0.1 seconds with 42 queries by YEKTAWEB 4645